      Gold-life micropump development and production center

      Homepage
      Favorite

      | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

      Select micro-pump

      pressure unit conversion table

      GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (mL/min)

      Weight

      (g)

      Pump Size

      Detailed Structure of the show

      reference Appearance

      GminiPA-1

      3.5

      30-50

      35

      -25

      800

      16

      162431

      >>here

      GminiPA-2

      3.5

      30-40

      35

      -20

      300

      16

      162431

      >>here

      Ibid

      pressure unit conversion table

      GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (mL/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Detailed Structure of the show

      reference Appearance

      GminiPB-1

      3.5

      100

      35

      -25

      800

      28

      162441

      >>here

      GminiPB-2

      3.5

      100

      35

      -20

      300

      28

      162441

      >>here

      Ibid

      GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPA-1

      1.5-5

      test:4V

      40-100

      50

      20-30

      0.3-1.5

      35

      402336

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPA-2

      2.0-5

      test:4V

      30-100

      50

      30-40

      0.5-2.0

      35

      402336

      Ibid

      Ibid

      GMPA-3

      3-6

      40-70

      50

      20-30

      0.5-1.5

      35

      402336

      Ibid

      Ibid

      GMPA-4

      3-6

      50-90

      50

      30-40

      0.5-1.8

      35

      402336

      Ibid

      Ibid

      GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPC-1/2/3

      6/9/12

      <200/120/90

      >100

      50-65

      2.5-3

      45

      502231

      Structure>>here

      flow-load diagram

      voltage-flow chart

      GMPC-4/5/6

      6/9/12

      <150/110/80

      >80

      50-55

      2.0-2.5

      45

      502231 ibid

      ibid

      GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPD-1/2/3

      6/12/24

      <230/130/80

      60-100

      60

      3-8

      82

      3544.556.5

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPD-4/5/6

      6/12/24

      <200/100/60

      60-100

      50

      3-7

      82

      3544.556.5 ibid

      ibid

      Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

      GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

      Name and model

      Voltage

      (V)

      No-load Current

      mA

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPE-1/2

      12/24

      <180/90

      60

      50-55

      3-6

      149

      33543.572

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPE-3/4/-

      12/24 -20-40 Custom 3L4L5L 149 3543.572

      Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

      GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPF25-1/2

      12/24 0.6/.3 >100 -70 25 480 8656.5126

      Structure>>here

      GMPF15-3/4

      12/24 0.6/0.3 >60 -50 18 480 8656.5126

      Structure>>here

      GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPG-1/2

      6-12/24

      <0.450

      100

      20-50

      36

      620

      8670126

      Structure>>here

      GMPG-3/4

      6-9/24

      <0.550

      100

      20-50

      36

      620

      8670126

      ibid

      GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPB-1/2

      6/12

      <0.25/0.135

      100

      series260

      -45-55

      series vacum

       -85

      single:22

      dual:2.8

      55

      244749

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GDMPB-3/4

      6/12

      <0.25/0.135

      100

      series260

      50-65

      single:2.52

      dual:3.8

      55

      244749

      ibid

      GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPC-1/2

      12/24

      <0.135/0.08

      100

      series260

      -45-55

      series vacum

      -75

      single

      22L/min

      dual

      2.8L/min

      75

      244751

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GDMPC-3/4

      12/24

      <0.135/0.08

      series

      260

      -50-65

      series vacum

      -80

      single:2.52

      dual:3.8

      5

      244751

      ibid

      GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

      Name and model

      Voltage

      (V)

      No-load Current

      mA

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPD-1/2

      12/24

      <200

      /135

      100

      -40-50

      series vacum

      -75

      single:72

      dual:10

      107

      354855.5

      GDMPD-3/4

      12/24

      <240

      /135

      100

      -40-60

      series vacum

      -80

      single:82

      dual:11

      107

      354855.5

      GDMPD-5/6

      12/24

      <180

      /115

      100

      -35-45

      single:52

      dual:8

      107

      354855.5

      GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

      Name and model

      Voltage

      (V)

      No-load Current

      mA

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPE-1/2

      12/24

      <180/100

      100

      -40-50

      series vacum

      -75

      single:62

      dual:10

      175

      354871.5

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPF(40)-1/2

      12/24

      0.80

      100

      20-60

      single:282

      dual:40

      618

      1056.5126

      voltage-flow chart

      Structure>>here

      GDMPF(25)-3/4

      12/24

      0.70

      100

      20-60

      single:202,

      dual:25

      663

      1056.5126

      ibid

      GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPG(50)-1/2

      6-12/24

      <1.0

      60

      20-50

      single:352

      dual:50

      759

      11070126

      Structure>>here

      GDMPG(35)-3/4

      6-12/24

      <1.0

      -50-60

      20-50

      single:252

      dual:50

      759

      11070126

      Structure>>here

      GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

      Name and model

      Voltage

      (V)

      No-load Current

      A

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

      Structure>>here

      GFMPE-3/4

      12/24

      <0.67/0.35.67

      --

      45

      Four:3-15

      375 4564.5124
      Other Four:1-10 375 4564.5124

      HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

      Name and model

      Voltage

      (V)

      No-load Current

      mA

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      HLA-2

      --

      50mL and 100mL two tranches.

      Help

      Categories

       